Editing Program Change Commands
To store a MIDI Program Change command in a Preset, start by selecting the desired Bank/Preset while in Preset
Mode as indicated by the display and the respective Preset LED. Then follow this procedure:
1. Press and hold the desired Preset Switch. After 3 seconds, the Display will indicate current Bank status, a decimal
point, and the current program change command in the center and rightmost segments (01 through 09). If there is
no Program Change command for this Preset, “- -” will be displayed instead.
2. Press the Mode/Store switch to underscore the center and rightmost display segments.
3. Enter a 2 digit program change number using the 10 Direct/Preset switches. You must enter a leading “0” (by
using the C10/PS-10 switch) for any numbers below 10. Example: For Program Change number 5, press switch
C10/PS-10, then C5/PS-5. If you make a mistake on any entry, press Bank/Return.
NOTE: PRESSING THE BANK/RETURN SWITCH IS AN EASY WAY TO CORRECT ANY WRONG ENTRY!
Example #2: Program Change #84: Press switch C8/PS-8, then switch C4/PS-4. NOTE: A number cannot be
entered without first underscoring the Display with the Mode/Store switch. The Program Change command is
automatically stored in the selected Bank/Preset. Any entry above 99 will be ignored.
4. Once in Program Change Edit mode, you can freely select any of the Presets in the current Bank to view and/or
edit existing Program Change commands.
5. To clear an existing Program Change command from a given Preset, enter 00 (by pressing the C10/PS-10 switch
twice).
6. To exit the Program Change Edit Mode, press the Bank/Return switch. You will now be in the Preset you were in
when you left Program Change Edit Mode.
Editing Direct Access Controller Numbers
Each of the 10 Direct Access/Preset switches can be assigned a MIDI Control Change number from 000 to 127. Any
numbers above 127 will be ignored. To enter Direct Controller Edit Mode, start by selecting Direct Access Mode from
any Preset (as indicated in the display) using the Mode/Store switch. Then follow this procedure:
1. Press and hold the desired Direct Access switch. After 3 seconds, the respective Direct Access switch LED will be
the only one lit and the Display will indicate the 3 digit MIDI Control Change number for that switch.
2. Press the Mode/Store switch to underscore the Display, then enter the new number using the 10 Direct/Preset
switches. Remember to enter leading “0”’s for numbers below 10 using the C10/PS-10 switch. Follow the same
procedure for entering numbers as you did with Program Change commands. Invalid entries will be ignored.
3. Use the Bank/Return switch to correct any errors or to move to the previous setting when entering numbers.
4. Once you are in Direct Controller Edit Mode, you can freely select any switch to view and/or edit any Direct Access
Controller number. Selection is mutually exclusive. That is, only one switch can be viewed at a time.
5. When finished programming, to return to Direct Access Mode, press Bank/Return. From there, to get to Preset
Mode, press Mode/Store.
“Power On” Setup Modes
There are several “Power on” procedures that can be used to make programming the RS-10MKII a little easier. They
each involve holding down a particular switch before applying power to the unit. Keep the switch held down until the
display shows the current Bank number. Then release. The RS-10MKII will retain these settings in memory until you
decide to change them. Programmed Presets will be retained except for the reset procedure (#7).
1. Press and hold switch C4/PS-4 on power up to program the Direct Access switches for CAE 4x4 control.
2. Press and hold switch C2/PS-2 on power up to program the Direct Access switches for CAE 2x4 control.
3. Press and hold switch C6/PS-6 on power up to program the Direct Access switches for CAE RL-8 control.
4. Press and hold switch C8/PS-8 on power up to program the Direct Access switches for Amp Sel+ control.
5. Press and hold switch C1/PS-1 on power up to set Program Change Commands from 1 to 128.
6. Press and hold switch C10/PS-10 on power up to set Program Change Commands from 0 to 127.
7. Press and hold switches Bank/Return and Mode/Store on power up to reset to factory default. NOTE: Factory
default settings are the same as 2x4 controller settings with no Program Changes sent.
8.Press and hold Bank Switch to change Midi Out channel from 1 to 16 (Version 1.1 software only).
Expanders
The RS-10MKII is capable of supporting up to 3 Expander Modules, each containing 8 Direct Access Controller
Switches. When using Expanders, the Direct Access switches are always available in either Preset or Direct Access
Mode on the RS-10MKII. Programming the Expander’s MIDI Control Change numbers is the same as on the
RS-10MKII. Connect the Expander to the RS-10MKII via the supplied 7 pin DIN cable with RS-10MKII power off.
Vista de pagina 2
1 2 3 4

Comentarios a estos manuales

Sin comentarios